HOME >> Medical and Pharmaceutical Equipments >> Operating Theatres, Emergency Rooms, Clinics Room Equipment and Apparatus

    • Freecare FF400-1 PinkFingertip Oximeter Pink Fingertip Oximeter

      Tiny, light and all-in-one integrated clip design
      Easy to carry
      LED screen with SpO2
      Measures PR and pulse strength
      Real-time spot check-up
      Single button interface
      Easy for operation
      Low battery power indicator
      Single button interface
      Battery type: two 1.5V AAA alkaline or rechargeable batteries
      Colors: blue or pink
      Dimensions: 63 x 34 x 33mm
      Net weight: 50g (batteries included)

    • Pink Fingertip Oximeter with LED Screen Single Button Interfa
    • Freecare Technology Limited

    • Freecare FH200 pulse oximeter Pulse Oximeter

      Description:
      This pulse oximeter is intended for non-invasive spot-check measurement of functional oxygen saturation of arterial hemoglobin (SpO2)
      Features:
      Small, light, and easy to carry and handle
      Large LED display and easy to read
      Automatic power-off
      Built-in Ni MH rechargeable battery
      With low battery indicator
      Dimension: 120 x 63 x 32mm
      Net weight: 300g

    • Portable Pulse Oximeter SPO2/PR Monitor with Built-in Recharge
    • Freecare Technology Limited

    • 300C Arm Digital Sphygmomanome 3CH 300C Blood Pressure Monitor

      Measuring range: 0 to 300mm 0 to 40.0kPa
      Measuring accuracy: and #177;0.4kPa and #177;3mm
      Minimum scale: 0.1kPa 1mm
      Memory: 120 group memories (person A and B)
      With date and clock display
      Auto shut-off (30s after idle)
      Battery: AA x 4, alkaline batteries
      Battery life: 2 months (at 3 minutes per day)
      Size: 150 x 105 x 55mm
      Net weight: 180g (including battery)

    • 3CH 300C Blood Pressure Monitor with Upper Arm Digital Sphygmo
    • Freecare Technology Limited

    • Upperarm Digital Sphygmomanome 3CH 300A Blood Pressure Monitor

      Measuring range: 0 to 300mm 0 to 40.0kPa
      Measuring accuracy: and #177;0.4kPa and #177;3mm
      Minimum scale: 0.1kPa 1mm
      Memory: 120 group memories (person A and B)
      With date and clock display
      Auto shut-off (30s after idle)
      Battery: AA x 4, alkaline batteries
      Battery life: 2 months (at 3 minutes per day)
      Size: 150 x 105 x 55mm
      Net weight: 180g (including battery)

    • 3CH 300A Blood Pressure Monitor with Upper Arm Digital Sphygmo
    • Freecare Technology Limited

    • Freecare 923A Electrocardiograph ECG Machine

      Features:
      Six channel with interpretive
      Built-in rechargeable Li battery
      Chinese English language
      Simultaneous 12 leads
      320 x 240 graphic LCD, 5.7-inch screen
      Paper size: 112mm x 20 30m
      Built-in RS232 interface (USB is optional)
      128 patients save copy communication
      Specification:
      Lead standard: 12leads
      lead acquisition: synchronously 12 leads
      Data acquisition 18bit 1,000Hz
      Record mode: manual mode; auto 1; auto 2; auto 3
      Filter: AC, EMG, drift filter
      CMRR: 100dB(with AC filter)
      Input circuit floating; protection circuit against defibrillator effect
      Input circuit current: >=0.1 and #956;A
      Input impedance: <=2.5M and #937;
      Patient current leakage: less than 10 and #956;A
      Calibrating voltage 1mV and #177;2锛?
      Voltage tolerance: and #177;500mV
      Time constant:>3.2s
      Frequency response: 0.05 to 150Hz
      Noise level: <=15 and #956;Vp-p
      Sensitivity valve: <=20 and #956;V
      Inter-channel interference: <=0.5mm
      Paper speed: 25, 50mm s( and #177;3锛?
      Sensitivity auto, 2.5, 5, 10, 20mm mV
      Recording mode: thermal array printing
      Paper specification 112mm x 30m, roll
      LCD display: 320 x 240 graphic LCD, display status and waveform
      Safety classification: IEC60601-1 class I, type CF
      Power supply: 110V 220V 110 to 230V AC, 50 60Hz and #177;1Hz; 30VA
      DC: 14.4V (2000mAh) rechargeable Li-ion battery
      Fuse AC extend T500mA 125V: and #216;5 x 20mm
      AC extend T400mA 250V: and #216;5 x 20mm
      AC extend T2.0A 250V: and #216;5 x 20mm

    • 6-channel Digital Electrocardiograph and ECG Machine with 5.7-
    • Freecare Technology Limited

    • Freecare FF404Fingertip Pulse Oximete Fingertip Pulse Oximeter

      Double color OLED display with 4 direction
      Single button interface and low battery power indicator
      SPO2 measuring range: 35 to 100 and #37;
      Pulse rate: 30 to 240bpm
      Pulse waveform display: bargraph display
      Battery indication: OLED display
      Power requirements: two AAA size 1.5V alkali battery
      Working current <=20mA
      SPO2 resolution: 1 and #37;
      SPO2 accuracy: and #177;2, 70 to 100 and #37;
      Unspecified: below 70 and #37;

    • Fingertip Pulse Oximeter with Double color OLED Display with 4
    • Freecare Technology Limited

    • Freecare FH211 Handheld Pulse Oximeter Pulse Oximeter

      Measurement objectors include adult, pediatric, infant and neonate
      Intelligent display of SpO2 waveform and data, PR, PLETH, pulse strength and temperature
      Prompting: battery capacity and speaker volume
      Alarm limits setup
      Audio and visual alarm
      Power saving: automatic shutdown when no monitoring
      Data storage, adding, and deletion
      Drawing trend waveforms with saving data
      Transmitting the patient s trend data to a PC for Display, observation, save, and print
      SpO2:
      Measurement range: 35 to 100 and #37;
      Resolution: 1 and #37;
      Accuracy:
      70 to 100 and #37;: and #177;2 and #37;
      0 to 69 and #37;: unspecified
      PR:
      Measurement range: 30 to 250bpm
      Resolution: 1bpm
      Accuracy: and #177;2bpm
      Channel: 1
      Input: body surface thermal sensitive resistor temperature sensor
      Temperature range: 0 to 50 degrees Celsius
      Resolution: 0.1 and #37;
      Accuracy: and #177;0.2 and #37;
      Power supply: three 1.5V AA alkaline or rechargeable batteries
      Color: blue or pink
      Standard accessories:
      One SpO2 adult finger probe
      One temperature skin face probe
      One PC software CD

    • Handheld Pulse Oximeter SPO2/Temperature Monitor with AA Batte
    • Freecare Technology Limited

    • Freecare FD301 portable fetal doppler Portable Fetal Doppler

      LCD display with backlight
      Can be used in any illumination conditions
      DSP technology is employed to assure accuracy and reliability of FHR detection
      High sensitivity probe with 2.0MHz in continuous wave
      Ergonomic design
      Portable and convenient
      Built-in speaker and sound frequency output port
      Automatically power off
      Multi-displaying of FHR: number, battery status indicator and voice intensity indicator
      Three working modes: real-time FHR display, mean FHR display and manual counting (option: 2.0MHz)
      FHR display: LCD
      Measurement range: 50 to 210bpm (option: 30 to 240bpm of 2.0MHz)
      Measurement accuracy: and #177;1 and #37; or and #177;1bpm
      LCD display dimensions: 39 x 27mm
      Speaker power: 1W
      Built-in chargeable nickel-hydrogen battery
      Working voltage: 9V
      Continuous operating time: >5 hours
      Temperature:
      Working: +5 to +40 degrees Celsius
      Transport and storage:-10 to +55 degrees Celsius
      Humidity:
      Working:

    • Portable Fetal Doppler with 2.0MHz Frequency and 9V Working Vo
    • Freecare Technology Limited

    • Freecare FD301-1 Fetal Doppler Fetal Doppler

      Allowing pregnant women for listening unborn baby heart beat
      Safe and easy to use
      Designed for home hospital use
      Suitable for obstetricians, midwives and pregnant women
      LCD display with backlight
      Used in any illumination conditions
      DSP technology is employed to assure accuracy and reliability of FHR detection
      High sensitivity probe with 1MHz in pulse wave
      Ergonomic design
      Portable and convenient
      Built-in speaker and sound frequency output port
      Automatically power off
      Multi-displaying FHR: number, battery status and voice intensity indicator
      Three working modes: real-time, mean FHR display and manual counting (option: 2.0MHz)
      Measurements:
      Range: 50 to 210bpm (option: 30 to 240bpm of 2.0MHz)
      Accuracy: 1bpm
      LCD display dimensions: 39 x 27mm
      Speaker power: 1W
      Built-in chargeable nickel-hydrogen battery
      Working voltage: 9V
      Continuous operating time: >5 hours
      Operating temperature: +5 to +40 and #0176;C
      Dimensions: 330 x 230 x 70mm
      Gross weight: 0.8kg
      Standard accessories: one probe, gel and battery charger

    • Fetal Doppler with 1.0MHz Frequency 9V Working Voltage and Er
    • Freecare Technology Limited

    • Freecare 901A Electrocardiograph ECG Machine

      Single channel with measurement report
      Built-in rechargeable Ni-MH battery
      Supports Chinese English
      Simultaneous 12 leads
      320 x 240 graphic LCD, 3.8-inch screen
      Paper size: 50 x 20 30m
      Built-in RS232 interface (USB is optional)
      8 patients save, copy and communication
      Lead standard 12 leads
      Lead acquisition synchronously 12 leads
      Data acquisition 18 bit 1000Hz
      Record mode: manual mode: auto 1, 2 and 3
      Filter AC, EMG and drift filter
      CMRR: 100dB (with AC filter)
      Input circuit floating
      Protection circuit against defibrillator effect
      Input circuit current <=0.1 and #956;A
      Input impedance: >=2.5M and #937;
      Patient leakage current: 10 and #956;A
      Calibrating voltage: 1mV and #177;2 and #37;
      Voltage tolerance: and #177;500mV
      Time constant: >3.2s
      Frequency response: 0.05 to 150Hz
      Noisy level: <=15 and #956;Vp-p
      Sensitivity valve: <=20 and #956;V
      Inter-channel interference: <=0.5mm
      Paper speed: 25 and 50mm s ( and #177;3 and #37;)
      Sensitivity: auto 2.5, 5, 10 and 20mm mV
      Recording mode: thermal array printing

    • 1CH Digital Electrocardiograph and ECG Machine with Larger Scr
    • Freecare Technology Limited

    • BB01 Monitor with BC01 Camera Baby Monitor

      This Baby Monitor allows 2.4GHz wireless audio visual transmission straight to the palm of your hand
      Simply switch on the monitor to instantly see or hear your baby from a distance of up to 100m in open space
      6-infrared LED lights on the camera enable night vision monitoring, and the optional
      Automatic voice activation switches the monitor ON when sound is detected
      Watch over your baby in comfort and ease
      Monitor:
      Power volume control
      Optional voice activation
      Channel selection button (select the channel you want by pressing a channel button)Note: you must select the same channel on the camera and on the monitor
      Power indicator LED
      Channel indicator LEDs
      Brightness adjustment button (seven levels of brightness control. The power LED will blink when pressing the (-) or (+) button to the highest or lowest level)
      Keyholes for the wall mount and plug
      Battery compartment
      7.5V DC power adapter plug
      AV output jack (mono sound)
      Full color
      Full audio and visual footage
      1.5-inch TFT LCD screen
      Transmits up to 100m in open space
      Includes AV Cable for connecting to TV monitor
      Includes wall mount and screws
      Monitor dimensions: 7.99 x 4.91 x 12cm
      Camera:
      Infrared LEDs
      Lens
      Lens head
      Microphone
      Keyholes
      Battery compartment

    • Baby Monitor with 1.5-inch TFT Screen Allows 2.4GHz Wireless
    • Freecare Technology Limited

    • Freecare or OEM FP131 Tabletop NIBP monitor Tabletop NIBP Patient Monitor

      Operates on AC, rechargeable battery power supply or common 1.5V AA alkaline battery
      Compact, small, light and easy for learning and handling
      Professional BP monitor for hospital and clinical
      Can measure patient s blood pressure accurately and send the saved data (up to 900-group) to PC for reviewing and printing
      Functional software can let doctor review and analyze the history data easier and faster
      Monitor is a non-invasive, tabletop patient monitor
      Suitable for monitoring adult and child patients
      Used in hospital operation room, ICU, clinic section office, out-patient department, sickroom, emergency treatment and the recovery and health care organizations or in the family nursing and in the process of transporting patients
      Parameters measured by the monitor include non-invasive blood pressure (NIBP) and pulse rate (PR)
      Monitor measures these parameters through a NIBP cuff then displays the measurements on the LED screen after certain further processing
      Monitor is operated and controlled by the buttons on the front panel
      Adapts a homochromy LCD screen and LED screen in displaying measurements and measuring state and a homochromy LED and a dual-color LED in supplementary status indication
      Capable of managing measured data and transmitting the patient trend through communication cable to a computer for displaying, observing, saving or printing

    • Tabletop NIBP Patient Monitor with PC Connectable Software Op
    • Freecare Technology Limited

    • Freecare 903 Electrocardiograph ECG Machine

      Features:
      Three channel with interpretive
      Built-in rechargeable Li battery
      Chinese English language
      Simultaneous 12 leads
      192 x 64 graphic LCD
      Paper size: 63mm x 20 30m
      Built-in RS232 interface (USB is optional)
      Specifications:
      Lead standard: 12 leads
      lead acquisition: synchronously 12 leads
      Data acquisition: 18bit 1000Hz
      Record mode: manual mode; auto 1; auto 2; auto 3
      Filter: AC, EMG, Drift Filter
      CMRR 100dB (with AC filter)
      Input circuit floating; protection circuit against defibrillator effect
      Input circuit current: <=0.1 and #956;A
      Input impedance: >=2.5M and #937;
      Patient current leakage: less than 10 and #956;A
      Calibrating voltage: 1mV and #177;2锛?
      Voltage tolerance: and #177;500mV
      Time constant: >3.2s
      Frequency response: 0.05 to 150Hz
      Noisy level: <=15 and #956;Vp-p
      Sensitivity valve: <=20 and #956;V
      Inter-channel interference: <=0.5mm
      Paper speed: 25, 50mm s ( and #177;3锛?
      Sensitivity auto, 2.5, 5, 10, 20mm mV
      Recording mode: thermal array printing
      Paper specification: 63mm x 30m, roll
      LCD display 192 x 64 graphic LCD, display status and waveform
      Safety classification: IEC60601-1 class I, type CF
      Power supply AC : 110V 220V 110 to 230V, 50 60Hz and #177;1Hz; 30VA
      DC: 14.4V (2,000mAh) rechargeable Li-ion battery
      Fuse AC extend T500mA 125V: and #216;5 x 20mm
      AC extend T400mA 250V: and #216;5 x 20mm
      AC extend T2.0A 250V: and #216;5 x 20mm

    • 3-channel Digital Electrocardiograph and ECG Machine with 1mV&
    • Freecare Technology Limited

    • Freecare FP130Vital Sign Monitor Oximeter Patient Monitor

      Vital sign monitor features:
      Compact
      Lightweight
      Easy to carry and handle
      With high-brightness LED display
      Storage of NIBP and SpO2 upto 800 groups
      Available with external printer
      Automatic power-off function
      Built-in Ni MH rechargeable battery
      Operates for 15 hours
      With low battery indicator
      Specifications:
      NIBP:
      Measurement method: oscillometric
      Patient range: adult and pediatric
      Measurement unit: mmHg kPa (selectable)
      Measurement range:
      Adult: 30 to 255mmHg
      Pediatric: 30 to 160mmHg
      Measurement modes: manual, auto and stat
      Measurement type: sys, dia and map
      Measuring interval in auto mode: 1, 2, 3, 5, 10, 15, 20, 30 and 60 minutes
      Measuring period in stat mode: 5 minutes
      Resolution: 1mmHg
      Over-pressure protection:
      Adult: 300mmHg
      Pediatric: 220mmHg
      Oxygen saturation (SpO2):
      Measurement rage: 35 to 100 and #37;
      Accuracy: and #177; 2 and #37; (70 to 100 and #37;) and 0 to 69 and #37; unspecified
      Resolution: 1 and #37;
      Pulse rate:
      Measurement range: 0 to 250bpm
      Accuracy: and #177; 1bpm
      Resolution: 1bpm
      Display mode:
      Parameter: 7 segment LEDs
      Information: fixed characters and icons lighted by single-color LEDs
      Optional: red for all display as left picture shown
      Red for SpO2 and bargraph
      Yellow for NIBP and others
      Power: dual-color LED segments
      External printer:
      Model: thermal micro printer
      Interface: TTL standard serial interface
      Power supply: 5V DC, maximum 3A
      Power requirements:
      Internal battery: lithium-ion rechargeable
      Operating time: 10 hours
      Recharge time: 12 hours
      Power: 100 to 240V DC, 50 to 60Hz and 10VA
      AC adapter for printer:
      Input: 100 to 240V, 50 to 60Hz and 0.7A
      Output: 5V DC, 3A
      Dimensions(W x D x H): 205 x 200 x 95mm
      Accessories:
      One adult cuff
      One pediatric cuff
      One charger
      One Spo2 fingertip sensor

    • Tabletop Pulse Oximeter Patient Monitor with Vital Signs NIBP
    • Freecare Technology Limited

    • Freecare FH210 Handheld Pulse Oximeter Pulse Oximeter

      Measurement objectors include adult, pediatric, infant, and neonate
      Intelligent display of SpO2 waveform and data, PR, PLETH, pulse strength, and temperature
      Prompting: battery capacity and speaker volume
      Alarm limits set-up
      Audio and visual alarm
      Power saving: automatic shutdown
      Data storage, adding, and deletion
      Drawing trend waveforms with saving data
      Transmitting the patient s trend data to a PC for display, observation, save, and print
      SpO2:
      Measurement range: 35 to 100 and #37;
      Resolution: 1 and #37;
      Accuracy:
      70 to 100 and #37;: and #177;2 and #37;
      0 to 69 and #37;: unspecified
      PR:
      Measurement range: 30 to 250bpm
      Resolution: 1bpm
      Accuracy: and #177;2bpm
      Channel: 1
      Input: body surface thermal sensitive resistor temperature sensor
      Temperature range: 0 to 50 degrees Celsius
      Resolution: 0.1 and #37;
      Accuracy: and #177;0.2 and #37;
      Working voltage: 6.0 to 9.0V DC
      AC power adaptor
      Input: 100 to 240V AC, 50 or 60Hz, 0.7A
      Output: 8V DC, 800mA
      Internal battery
      Type: 2Ahr 6V Ni-MH rechargeable battery
      Run time: 15-hour continuous operation with a new, fully charged battery
      Recharge time: 10 hours
      Another model FH211 apply with three 1.5V AA alkaline or rechargeable batteries
      Color: blue or pink
      Standard accessories:
      One SpO2 adult finger probe
      One temperature skin face probe
      One Adaptor and one free-charge software CD

    • Handheld Pulse Oximeter SPO2/Temperature Monitor with Free PC
    • Freecare Technology Limited

    • Freecare FH201 pulse oximeter Pulse Oximeter

      FH201 pulse oximeter with AA size battery
      Parameter: Pulse rate, SpO2
      Measurement: adult, pediatric, infant, neonate, and animal
      Applys with 9-pin D type connector SPo2 sensor
      Alarm set-up easier with button on the panel
      Three standard AA size alkaline batteries or rechargable batteries
      Fulfill CE saftety and EMC requirement
      Automatically power-off
      Audiable and visible alarm ,with 2-level volume adjustable
      Net Weight: 130g

    • Portable Pulse Oximeter SPO2/PR Monitor with AA size Battery
    • Freecare Technology Limited

    • BJ All kinds of operating lamps operating lamp surgical light operation light surgery light

      Illuminance (at the distance of 1m): ≥80,000 / ≥80,000 lux. Color Temperature: 4500±500K. Adjustment range of illuminate Field diameter: 160-280mm Operator head temperature rise: ≤2ºC Work Area temperature rise: ≤12ºC Illuminance depth: ≥600mm Color rendering index (Ra): ≥92 Main Supply: 220V model standard, 110V model available 24V Bulb Power Consumption: 150/150 W Brightness adjustment: 8-stage continuous light adjustment Removable, sterilizable handle Reserve bulb with auto-switchover, in case of primary bulb failure Advanced suspension arm design, providing smooth, extensive coverage Quartz/Halogen bulbs, Easily replaceable, low cost, long life Available as wall, portable floor, single or dual ceiling mounts

    • operating lamp surgical light operation light