HOME >> Security & Protection >> Fire Detecting and Alarm Equipments

    • CL-183 Two-Wire Heat Detector

      Input voltage range: 16VDC to 32VDC
      Alarm current: 10mA to 100mA maximum
      Standby current:
      35uA peak at 24VDC
      30uA peak at 16VDC
      Environmental temperature: 32 to 140 degrees Fahrenheit
      Humidity: 0 percent to 95 percent RH
      Detector sensitivity: 30 seconds plus 86 degrees Fahrenheit

    • Two-Wire Heat Detector (Rate-of-Rise) with CE Approval Taiwan
    • Chang Long Fire Protection Inc

    • CL-181H CE-Approved Heat Detector

      Input voltage range: 16VDC to 32VDC
      Alarm current: 10mA to 100mA maximum
      Standby current: 35uA at 24VDC
      Environmental temperature: 32 to 100 degrees Fahrenheit
      Humidity: 0 percent to 95 percent RH
      Detector sensitivity: 135 degrees Fahrenheit

    • CE-Approved Heat Detector with Two-Wire or Four-Wire Options
    • Chang Long Fire Protection Inc

    • CL-188 Single Station Smoke Detector

      Power: 9VDC battery
      Alarm current: DC, 100mA
      Nominal sensitivity: 2.3 + - 1.2 percent feet obscuration
      Low battery warning: unit beeps every 50 seconds for 7 days (minimum) to indicate a need of battery replacement
      Battery life: over one year
      Loudness: 85dB piezoelectric alarm

    • Single Station Smoke Detector (Wireless) with CE approved 85dB
    • Chang Long Fire Protection Inc

    • CL-207L Alarm Siren Electronic Fire Bell Featuring

      Input voltage: 24VDC (12VDC to 30VDC), with reverse polarity protection
      Operation current: fire bell with strobe LED, 50mA, 65mA max. at 24VDC
      Strobe: over 8,000mcd (6 pcs super bright LEDs)
      Sound output: 100dB + - 5dB at 24VD)
      Tone type: alarm siren
      Operation temperature: -10 to +60 degrees Celsius
      Continue operation test at 24VDC: over 72 hours
      Life test: on: 1 minute, off: 30 seconds
      Duty cycle at 24VDC: continuously over 500 hours period
      Size: 81.5 x 81.5 x 52mm (fit European junction box)

    • Alarm Siren Electronic Fire Bell Featuring with Strobe LED Ta
    • Chang Long Fire Protection Inc

    • CL-2100E-28 28-Zone Fire Control Alarm Panel

      Input voltage: 240VAC (50 60Hz) + -10 percent
      Battery: 24VDC
      Charging voltage protection: 1.6Ah glass fuse
      Sounder output: 24V nominal EOL 10K resistor
      Auxiliary contacts: 30VDC, 1A max. NC NO
      Main supply protection: glass fuse
      Sounder protection: 2 x 500mA glass fuse
      Reverse battery protection: charger glass fuse
      Zone EOL: 5.6K resistor
      Color: ivory
      Zoned visual red alarm and yellow trouble indicators
      Continuous signal during alarm
      Built-in battery charger
      Low no power and battery detection
      Automatic loading and testing of battery
      Battery lead reversal protection
      Evacuate (alarm resound)
      LED test

    • 28-Zone Fire Control Alarm Panel 100 Zones Maximum Available
    • Chang Long Fire Protection Inc

    • CL-180T CE-Approved Combined Smoke and Heat Detector

      Input voltage range: 16VDC to 32VDC
      Alarm current: 10mA to 100mA maximum
      Standby current:
      60uA average, 90uA peak at 24VDC
      40uA average, 60uA peak at 16VDC
      Humidity: 0 percent to 95 percent RH
      Detector sensitivity: nominal set at 10 percent 50cm
      Set temperature: 135 degrees Fahrenheit

    • CE-Approved Combined Smoke and Heat Detector in Two-Wire or Fo
    • Chang Long Fire Protection Inc

    • CL-207 24VDC Electronic Fire Bell

      Input voltage: 24VDC (12VDC to 30VDC), with reverse polarity protection
      Operation current: only 22mA, 28mA max. at 24VDC
      Sound output: 100dB + - 5dB at 24VDC
      Tone type: sweep siren
      Operation temperature: -10 to +60 degrees Celsius
      Continue operation test at 24VDC: over 72 hours
      Life test: on: 1 minute, off: 30 seconds
      Duty cycle at 24VDC: continuously over 500 hours period
      Size: 81.5 x 81.5 x 32mm (fit European junction box)

    • 24VDC Electronic Fire Bell with Sweep Siren Tone Type Taiwan
    • Chang Long Fire Protection Inc

    • CL-187 Single Station Heat Detector

      Power: 9VDC battery
      Heat sensor set point: 113 degrees Fahrenheit (45 degrees Celsius)
      Relative humidity: 0 percent to 95 percent RH
      Sound: loud 85dB alarm signal
      Test function: press testing button
      Monitoring LED: every 35 seconds
      Alarm LED: flash
      Material: ABS polycarbonate
      Low battery warning: unit beeps every 35 seconds for 7 days (minimum) to indicate battery need replacing
      Battery life: over one year
      Appearance: ivory color
      Weight : 128g
      Diameter: 12.6cm
      Height: 3.5cm

    • Single Station Heat Detector (Wireless) Powered by 9VDC Batter
    • Chang Long Fire Protection Inc

    • CL-192 Emergency Lighting

      Power: 110VAC or 220VAC (50Hz to 60Hz)
      Current: 0.1A (maximum)
      Battery: DC 6V, 4Ah
      Charging time: 36 hours (minimum)
      Shining time: 90 minutes (over)
      Fluorescent tube: PL 13W x 1
      Color: ivory
      Material: ABS polycarbonate
      Size: 210 x 106 x 87mm
      Weight: 1160g

    • Emergency Lighting (PL) with Convex Rectangular Block Casing
    • Chang Long Fire Protection Inc

    • CL-182 Rate-of-Rise Heat Detector

      Input voltage range: 16VDC to 32VDC
      Alarm current: 10mA to 100mA maximum
      Standby current: 35uA at 24VDC
      Environmental temperature: 32 to 140 degrees Fahrenheit
      Humidity: 0 percent to 95 percent RH
      Detector sensitivity: 30 seconds plus 86 degrees Fahrenheit

    • Rate-of-Rise Heat Detector with Two-Wire or Four-Wire Options
    • Chang Long Fire Protection Inc

    • CL-201 24V Alarm

      Input voltage: 24VDC
      Alarm current: DC, 21mA (LED)
      Material for lamp cover: glass- or fire-retardant plastic
      Material for lamp base: fire-retardant plastic
      Size: 9 x 5.5cm

    • 24V Alarm Indicating Light in Fire-Retardant Plastic Material
    • Chang Long Fire Protection Inc

    • ORENA OT701 Photoelectronics Smoke Alarm

      Advanced photoelectric smoke sensing technology Sleek ergonomic design Very loud alarm horn, exceeding 90dB at 10 feet Test button for verify battery status and alarm operation Low-battery warning Mounting bracket and screws Easy install, move and maintain

    • smoke alarm smoke detector alarm
    • AHG AHG9600 Fire Alarm Panel

      The AHG9600 Fire Alarm Control System of the Xinwo Company combines with the computer technology, network technology, distributed intelligence, automatic recognition, automatic addressing, networking, graphics, auto-diagnosis and other advanced technologies so as to promote the system to become easier in design, construction, debugging, operation and maintenance etc and ensure it to become obviously superior to other similar products in reliability, economy and convenience for use etc, which can meet the most stringent requirements of the modern buildings on the fire alarm system. AHG9600 fire alarm panel adopts advanced modular structure design and are connected with the intelligent detector, intelligent call point and matching monitoring & control module through the two-bus circular loop (AHGBUS), which constitutes an completely intelligent and high-quality automatic fire alarm control system.

    • two-bus circular loop Fire Alarm Panel Intelligent
    • AHG 992001 Intelligent Fire Detector

      They adopt SMT techniques and built-in micro-computers and conduct a comprehensive assessment on sensor signal amplitude measurement, time analog and fire parameters etc by means of the modern micro-processing technology and numerical algorithms to determine false or true fire information, which realizes the intelligent distribution of the fire alarm system. The AHGBUS series detectors adopt unique broadcast-type interactive communications, digital signal working mode and micro-power design etc so as to technically ensure their superior anti-electromagnetic interference capability and almost zero false alarm rate.

    • Fire Alarm Smoke Detector
    • AHG 992004 Intelligent Fire Detector

      They adopt SMT techniques and built-in micro-computers and conduct a comprehensive assessment on sensor signal amplitude measurement, time analog and fire parameters etc by means of the modern micro-processing technology and numerical algorithms to determine false or true fire information, which realizes the intelligent distribution of the fire alarm system. The AHGBUS series detectors adopt unique broadcast-type interactive communications, digital signal working mode and micro-power design etc so as to technically ensure their superior anti-electromagnetic interference capability and almost zero false alarm rate.

    • Fire Detector Fire Alarm ROR Heat
    • AHG 992010 Manual Call Point

      AHG992010 call point is specially designed for the AHGBUS circular loop technology, adopt SMT techniques, and occupy one address point of the bus. In the event of a fire, press the button and the alarm indicator lamp is on for alarming. The AHG9600 fire alarm panel can accurately indicate the address of the alarm button. A dry contact signal input designed in the button can connect with the feedback signals from the button starting pump of the hydrant. At the same time a phone jack is provided for convenient contact with the Fire Service Center.

    • Fire Alarm Manual Call Point MCP
    • AHG 992012 992030 Monitoring Control Module

      AHG2030 and AHG2012 input and output modules are specially designed for the AHGBUS circular loop technology, adopt SMT techniques and hence share strong anti-interference capability. The AHG2030 input and output modules provide a switch input signal and a relay output. The AHG2012 input and output modules are used for connecting four switch input signals and two relay outputs. Each input of the modules is used to connect the standard detectors and switch input signals. The relay outputs of the modules can be programmed at will so as to control the equipment. It is mainly used to start or stop the blowers, exhaust blowers and elevators, and cut off the power supply for fire-resistance rolling shutters and fire pumps etc.

    • TRANSPONDERS Monitoring Module